Technical Description
|
Method of scanning
|
optical
|
|
Fingerprint scanning window
|
25,5 * 18 ìì
|
|
Resolution
|
508 dpi
|
|
Speed of scanning
|
1/15 ñ
|
|
False Acceptance Rate
of unauthorized access)
|
10-9 (1 case out of 1 000 000 000)
|
|
Dimensions (length * width * hight)
|
45 * 63 * 26 ìì
|
|
Âåñ
|
120 ã
|
|
Interface
|
USB 2.0/1.1, plug&play, cable of 2 m in the set of deliverry
|
|
Temperature of operation
|
îò -10°Ñ äî +55°Ñ
|
|
Humidity (without condensate)
|
îò 30% äî 90%
|
|
Power comsumption (on USB)
|
350 mVt (scnning mode)
100 ìÂò (Standby mode)
40 ìÂò ("sleeping" mode)
|
|
Embodiment
|
desk-size embodiment
|
Systems Requirements
- Pentuim 200 MHz, 32 Ìb RAM and higher(64 Ìb RAM recommended)
- Microsoft Windows 98/ME/NT/2000/XP/2003/Vista
- free USB-port
- any of sowtware products of: BioLink - IDenium, BioTime, Authentication Center 5.õ, SDK 5.õ and higher, any other software developed on the basis of BioLink SDK
BioLink U-Match 5.0
Office fingerprint scanner with a smart-card reader
|
Scanner BioLink U-Match 5.0 integrates technologies of biometric identification and smart-cards, affording an opportunity of using of these technologies both in a complex and separately
|
Technical Description
|
Mode of scanning
|
optical
|
|
Fingerprints scanning window
|
25,5 * 18 ìì
|
|
Resolution
|
508 dpi
|
|
Speed of scanning
|
1/15 ñ
|
|
False Acceptance Rate
of unauthorized access)
|
10-9 (1 case out of 1 000 000 000)
|
|
Supported standards of smart-cards
|
ISO 7816, EMV 2000
|
|
Supported power supply of smart-cards
|
5Â, 3Â è 1,8 Â
|
|
Smart-card type recognition
|
is done automatically
|
|
Speed of information exchange with the card
|
äî 119 Êá/ñ
|
|
Power consumption for the work with the card
|
300 ìÂò
|
|
LED indicator of state
|
green (free), red (engaged)
|
|
Additional scope of work with the card
|
8 pin handling (C4/C8 supported)
|
|
Dimensions (length * width * hight)
|
50 * 73 * 35 mm
|
|
Weigh
|
160 g
|
|
Interface
|
USB 2.0/1.1, plug&play, cable of 2 m is in the set of delivery
|
|
Temperature of Operation
|
îò -10°Ñ äî +55°Ñ
|
|
Humidity (without condensate)
|
from 30% to 90%
|
|
Power consumption (on USB)
|
350 ìÂò (Scanning mode)
100 ìÂò (Standby mode)
40 ìÂò ("sleeping" mode)
|
|
Embodiment
|
Desk-size embodiment
|
System Requirements
- Pentuim 200 MHz, 128 Ìb RAM (not less)
- Microsoft Windows 2000/XP/2003/ Vista
- free USB-port